SOLARWALL TECHNOLOGY & SOLUTIONS

How SolarWall heats industrial air.

Solar collectors, building integration, controls and system options for ventilation and process air.

THE TECHNOLOGY, EXPLAINED

How the collector heats incoming air.

A dark, micro-perforated absorber on a sun-facing façade or roof captures solar energy. Fans draw outdoor air through the perforations into an air cavity, then into the facility’s air-handling system or process air supply. This offsets heat that would otherwise be supplied by boilers, burners or other conventional equipment.

SolarWall heats air directly rather than producing electricity. The collector itself contains no liquid circuit, although the complete installation includes fans, dampers, ducts and controls.

Technical reference (Türkiye) →
SolarWall industrial building façade with sunlight
01 / Solar radiationAbsorber surface heats
02 / Air intakeAir passes through micro-perforations
03 / TransferWarm air enters the plenum and ductwork
04 / Useful heatAir feeds HVAC or a process line
ENGINEERING PRINCIPLES

What makes a solar air system perform?

A SolarWall collector belongs to a complete air-handling system. The useful result depends on absorption, pressure and airflow, solar exposure, duty cycle, controls and the baseline heat supply.

01 / TRANSPIRED ABSORBER

Direct solar-to-air transfer

A perforated metal absorber receives solar radiation; ventilation fans draw fresh air through the warm surface. The process avoids a separate fluid loop for basic air preheating.

02 / AIRFLOW

Air rate drives usable heat

SolarWall Global describes 2–10 cfm per square foot of collector in industrial configurations, depending on project design. Fan duty, plenum pressure and distribution affect the outcome.

03 / TEMPERATURE

Thermal lift depends on the day

SolarWall Türkiye publishes indicative diffuse-light lifts of 5–15 °C and sunny-day values of 25–40 °C for its Single-Stage descriptions. These are indicative rather than guaranteed for a facility.

04 / INTEGRATION

Connect to existing AHU systems

Coordinate supply ducting, air-handling units, fan and damper controls, heating-coil backup and the summer bypass with required air quality and process conditions.

05 / CONTROL

Solar heat only when useful

Control strategies compare collector and ambient temperatures with the required setpoint, schedule and process operating state; integration may include roof heat or return-air blending.

06 / MEASUREMENT

Make reported savings auditable

Instrument collector inlet and outlet temperatures, air volume, weather inputs, relevant damper states and baseline energy. Report delivered useful kWh separately from calculated fuel displacement.

60–85%*SolarWall Türkiye publishes this indicative thermal-efficiency range for certain configurations. Actual installed-system results depend on collector specification, air flow, weather and operating schedule.

*Published manufacturer indicative range, not a blanket warranty, measured result or an input for site-specific energy budgeting. Sources: SolarWall Türkiye, Teknolojiler; SolarWall Global, Industrial and Technology; NREL published research.

Explore the engineering briefing →
SOLUTION 01 / FACADE-INTEGRATED VENTILATION AIR HEATING

SolarWall® Single-Stage

Original transpired solar collector with a micro-perforated metal façade and a plenum connected to existing air-handling equipment. Suitable for retrofit and new-build industrial facilities.

200–1,000 W/m²Reported collector output range
Engineered to siteAirflow, orientation, climate and thermal load
SolarWall® Single-Stage illustrative SolarWall archive image
Photograph or technical illustration from the SolarWall archive; representation of technology, not necessarily this specific system configuration.
01 / system configuration

Key features

  • Direct solar preheating of incoming ventilation or process air
  • Perforated absorber, cavity and insulated connection to the air-handling unit
  • Panel profiles and colours can be adapted to the building, subject to thermal considerations
02 / business value

Advantages

  • Displaces part of seasonal purchased heating energy
  • Makes use of a façade area as a renewable heat resource
  • Can improve comfort through tempered make-up air and airflow management
03 / engineering

Integration potential

  • Central AHUs, rooftop HVAC units and fresh-air ductwork
  • Dampers, sensors, summer bypass and control-system interfaces
  • Integration design depends on pressure drop, required supply temperature and airflow
04 / industry fit

Applications

  • Automotive and general manufacturing
  • Warehouses, logistics centres and assembly halls
  • Commercial buildings with substantial outdoor-air requirements

Technical ranges and system descriptions derive from SolarWall Türkiye or manufacturer literature. Actual output, temperature lift, energy displacement and economic return are project-specific and must be validated in an engineering feasibility study.

SOLUTION 02 / HIGHER TEMPERATURE LIFT FOR DEMANDING FACILITIES

SolarWall® Two-Stage

A two-stage collector that heats incoming air in successive steps, with additional protection against wind-related heat losses. Particularly relevant to industrial sites requiring greater preheat temperatures.

300–1,100 W/m²SolarWall Türkiye reported thermal range
Engineered to siteAirflow, orientation, climate and thermal load
SolarWall® Two-Stage illustrative SolarWall archive image
Photograph or technical illustration from the SolarWall archive; representation of technology, not necessarily this specific system configuration.
01 / system configuration

Key features

  • Two successive heating stages using the solar air collector
  • Manufacturer describes a glazed second-stage configuration
  • Engineered for increased air temperature rise and higher thermal duty
02 / business value

Advantages

  • Improved thermal lift compared with the original single-stage approach
  • Potential fuel displacement for high-demand make-up air
  • Useful option for certain windy or roof-constrained sites
03 / engineering

Integration potential

  • Existing AHU systems, process air supply and rooftop arrangements
  • Temperature sensors, proportional dampers and BMS coordination
  • System choice depends on outdoor temperature and required thermal setpoint
04 / industry fit

Applications

  • Paint shops and industrial drying
  • Manufacturing with high outdoor-air demand
  • Facilities needing higher supply-air temperature

Technical ranges and system descriptions derive from SolarWall Türkiye or manufacturer literature. Actual output, temperature lift, energy displacement and economic return are project-specific and must be validated in an engineering feasibility study.

SOLUTION 03 / ROOFTOP SOLAR AIR HEATING FOR RETROFIT PROJECTS

SolarDuct® 1-Stage

A modular, duct-type roof collector developed for facilities where the façade is unavailable or a roof-based solution is more practical.

Roof-basedAlternative to façade mounting
Engineered to siteAirflow, orientation, climate and thermal load
SolarDuct® 1-Stage illustrative SolarWall archive image
Photograph or technical illustration from the SolarWall archive; representation of technology, not necessarily this specific system configuration.
01 / system configuration

Key features

  • Roof-mounted one-stage solar air heating configuration
  • Modular collector sections and duct connections
  • Designed to supply preheated intake air to building systems
02 / business value

Advantages

  • Utilises suitable roof area instead of the façade
  • Can be considered for retrofit projects with clear air-duct access
  • Modular form helps accommodate different roof layouts
03 / engineering

Integration potential

  • Feeds air-handling units via insulated duct connections
  • Airflow, roof loading and maintenance access must be reviewed
  • Controls can blend preheated air with ambient fresh air
04 / industry fit

Applications

  • Logistics buildings and warehouses
  • Medium-airflow manufacturing spaces
  • Commercial buildings without suitable solar-facing walls

Technical ranges and system descriptions derive from SolarWall Türkiye or manufacturer literature. Actual output, temperature lift, energy displacement and economic return are project-specific and must be validated in an engineering feasibility study.

SOLUTION 04 / MORE THERMAL LIFT FROM ROOF-MOUNTED COLLECTORS

SolarDuct® 2-Stage

A roof-based, two-stage configuration for air systems with demanding temperature and airflow requirements, subject to suitable roof capacity and weather exposure.

2 heating stagesRoof-mounted design
Engineered to siteAirflow, orientation, climate and thermal load
SolarDuct® 2-Stage illustrative SolarWall archive image
Photograph or technical illustration from the SolarWall archive; representation of technology, not necessarily this specific system configuration.
01 / system configuration

Key features

  • Two-stage modular duct collector
  • Roof installation with insulated process-air connections
  • Air-path arrangement tailored to temperature rise requirements
02 / business value

Advantages

  • Supports higher preheat temperatures in suitable conditions
  • Creates another design route where façade installations are impractical
  • Useful for process applications with significant thermal loads
03 / engineering

Integration potential

  • Fresh-air lines, rooftop equipment and process systems
  • Proportional damper control, bypass and BMS compatibility
  • Requires project-specific fan pressure and thermal calculations
04 / industry fit

Applications

  • Automotive paint facilities
  • Food processing and industrial drying
  • High-volume industrial ventilation

Technical ranges and system descriptions derive from SolarWall Türkiye or manufacturer literature. Actual output, temperature lift, energy displacement and economic return are project-specific and must be validated in an engineering feasibility study.

SOLUTION 05 / SOLAR HEAT FOR RECIRCULATING INDOOR AIR

Two-Stage Closed-Loop

An application concept described by SolarWall Türkiye that heats recirculated building air in two stages for certain space-heating demands. Suitability must account for indoor air quality and process ventilation obligations.

RecirculationSubject to indoor air standards
Engineered to siteAirflow, orientation, climate and thermal load
Two-Stage Closed-Loop illustrative SolarWall archive image
Photograph or technical illustration from the SolarWall archive; representation of technology, not necessarily this specific system configuration.
01 / system configuration

Key features

  • Two-stage thermal collection configuration
  • Air is recirculated through the heating loop
  • Can be configured for facilities where indoor air reuse is acceptable
02 / business value

Advantages

  • Supports high-bay space-heating requirements
  • Can contribute to more even temperatures in suitable facilities
  • Avoids unnecessary outside-air load where recirculation is permitted
03 / engineering

Integration potential

  • Mechanical recirculation and mixing units
  • Thermostatic and BMS controls
  • Fresh-air minimums and contaminant controls remain mandatory
04 / industry fit

Applications

  • High-bay production halls
  • Assembly and packaging areas
  • Suitable warehouses and workshops

Technical ranges and system descriptions derive from SolarWall Türkiye or manufacturer literature. Actual output, temperature lift, energy displacement and economic return are project-specific and must be validated in an engineering feasibility study.

SOLUTION 06 / USEFUL HEAT AND ELECTRICITY FROM THE SAME SURFACE

SolarWall® PV/T

PV modules generate electricity while a SolarWall thermal collector behind or adjacent to them extracts useful heat. It can improve use of a limited building envelope when both thermal and electrical loads exist.

Heat + powerIntegrated energy use
Engineered to siteAirflow, orientation, climate and thermal load
SolarWall PV/T panels with photovoltaic components installed
Photograph or technical illustration from the SolarWall archive; representation of technology, not necessarily this specific system configuration.
01 / system configuration

Key features

  • Combines photovoltaic conversion with a solar air collector
  • Extracts heat from the back of the PV array
  • Roof and façade applications depend on certified product configuration
02 / business value

Advantages

  • Two useful energy streams from the same available area
  • May reduce PV module operating temperature in suitable designs
  • Can supply preheated air to an HVAC system
03 / engineering

Integration potential

  • PV electrical installation and thermal air path are separately engineered
  • May integrate with heat pumps and building energy management
  • Electrical output and useful heat must be modelled independently
04 / industry fit

Applications

  • Industrial facilities with roof limitations
  • Large commercial buildings
  • Sites with simultaneous electricity and preheat requirements

Technical ranges and system descriptions derive from SolarWall Türkiye or manufacturer literature. Actual output, temperature lift, energy displacement and economic return are project-specific and must be validated in an engineering feasibility study.

SOLUTION 07 / NIGHT-TIME RADIATIVE COOLING SUPPORT

NightSolar®

A manufacturer-described configuration that uses night-sky radiative cooling to reduce incoming air temperature during suitable clear-sky conditions. It is not a substitute for cooling load calculations or required ventilation controls.

Night coolingClimate-dependent operation
Engineered to siteAirflow, orientation, climate and thermal load
NightSolar® illustrative SolarWall archive image
Photograph or technical illustration from the SolarWall archive; representation of technology, not necessarily this specific system configuration.
01 / system configuration

Key features

  • Uses thermal radiation from the collector surface to the night sky
  • Can draw air over a cooler surface
  • Functions are climate, humidity and sky-condition dependent
02 / business value

Advantages

  • Potentially reduces mechanical cooling demand
  • May support night ventilation strategies
  • Can complement day-time thermal solar operation
03 / engineering

Integration potential

  • AHUs, ventilation and BMS controls
  • Fans may still consume electricity
  • Condensation, humidity, outdoor-air quality and control priorities need study
04 / industry fit

Applications

  • Industrial and logistics buildings
  • Commercial premises in warmer climates
  • Buildings with suitable night-time ventilation strategy

Technical ranges and system descriptions derive from SolarWall Türkiye or manufacturer literature. Actual output, temperature lift, energy displacement and economic return are project-specific and must be validated in an engineering feasibility study.

ENGINEERING INTEGRATION

From solar collector
to useful heat.

Air handling integration

Ventilation schedules, fresh-air volume, pressure losses, fan selection, mixing requirements and winter/summer operating modes are modelled before equipment selection.

Controls and measurement

Temperature and flow measurement, proportional dampers, bypass devices and BMS logic are designed to supply useful heat at the appropriate conditions and monitor performance.

Technical references: Conserval technology catalogue → and SolarWall Türkiye detailed systems →.

FIND THE RIGHT CONFIGURATION

Which system fits
your facility?

Start with heat demand, air volume and available solar-facing surfaces.

Request an assessment ↗

Explore project economics and funding