The sun warms the perforated metal collector mounted on the building.

Industrial Heat.
Powered by the Sun.
SolarWall uses solar energy to preheat air for industrial ventilation and processes, helping facilities reduce fossil fuel demand, heating costs and operational emissions.
AUTOMOTIVE · AEROSPACE · MANUFACTURING · HOME APPLIANCES · FOOD & BEVERAGE · PACKAGING · HOSPITALS · TOBACCO DRYING
Selected project references
Solar energy preheats the air your facility needs.
SolarWall uses a sun-facing perforated metal collector to warm outside air before it enters the ventilation system. This reduces the heat that conventional equipment needs to supply.

Ventilation fans pull fresh air through the small openings.
Air picks up heat as it passes through the collector and cavity.
Preheated air enters the ventilation or process air system.
Industrial decarbonisation
Decarbonising industrial heating.
SolarWall uses sunlight to preheat incoming air for industrial ventilation and processes, helping facilities reduce conventional heating demand, operating emissions and costs.
Lower direct heating emissions
When solar-preheated air displaces on-site gas or other fuel combustion, direct emissions from industrial heating can fall.
Lower purchased energy demand
Where SolarWall reduces purchased electricity, steam or heat consumption, associated indirect emissions may also decrease.
Plan your solar heating investment.
We assess local climate and solar exposure, suitable south-facing façades or roof areas, and your facility’s annual production and heating demand before modelling expected useful heat, savings and investment options.
Location-specific weather and irradiation, shading, south-facing façade or roof suitability.
Heating hours, airflow and seasonal demand aligned with the facility’s production schedule.
Modelled solar heat, fuel savings, CO₂e reductions, payback and potential funding options.
Turn your building envelope into a source of heat.
SolarWall® uses sunlight to warm outdoor air before it enters a factory's ventilation system or industrial process. The result is useful renewable thermal energy that can reduce the amount of conventional fuel required.
Installed on suitable façades or rooftops, the technology is engineered to work with your air handling equipment, airflow demand and operating profile.
How SolarWall works →
SOLARWALL / INDUSTRIAL SOLAR AIR HEATINGProven across industries.
Built for real facilities.
Canadian-developed technology with an international record of industrial installations.
One technology.
Multiple industrial uses.
Wall-mounted and rooftop configurations designed around thermal requirements, available space and existing HVAC equipment.

Single-Stage SolarWall®
A micro-perforated metal collector integrated with a wall to preheat incoming ventilation or process air.
Factory ventilation · Warehouses · Retrofitting
Two-Stage SolarWall®
Two-pass collector design for sites requiring additional thermal lift, considered against the process temperature and airflow requirements.
Paint shops · Process air · Industrial heating
SolarDuct®
Rooftop-mounted collector option for buildings where a suitable façade is unavailable or roof integration is preferred.
Large roofs · HVAC integration · RetrofitsDesigned around
industrial demand.
From high-volume ventilation to production processes, each project begins with the energy load rather than a one-size-fits-all system.

Automotive manufacturing
Ventilation air preheating for production halls and paint shops.
View sector projects ↗
Aerospace & defence
Process ventilation for facilities with demanding air requirements.
View sector projects ↗
Food & beverage
Process air preheating for food and beverage production, including malt drying.
View sector projects ↗
Building materials
Solar air heating for ceramics and other heat-intensive materials processes.
View sector projects ↗
Manufacturing
Production halls, ventilation and industrial heating loads.
View applications ↗
Home appliances
Heating and fresh-air solutions for appliance production facilities.
View applications ↗
Tobacco drying
Solar-assisted process-air preheating for tobacco production.
View applications ↗Selected industrial
projects.
Explore documented installations and selected engineering studies across international industrial facilities.

Toyota Motor Manufacturing
Automotive
Solar air heating integrated into automotive production.

Bombardier
Aerospace & transport
Industrial solar air heating application.

Marks & Spencer
Retail & logistics
Solar air heating for commercial facilities.

Philip Morris
Tobacco manufacturing
50 m² SolarWall TSC at the Torbalı facility, preheating air for tobacco drying. Reported 265,000 kWh thermal energy annually.
View SolarWall case study →
Turkish Aerospace
Aerospace & defence
Solar air preheating integrated with an aerospace manufacturing facility.
View case study ↗
NASA | Dryden Flight Research CenterNASA aircraft hangar
Aerospace & defence
Documented SolarWall ventilation air heating on Hangar 1623 (372 m² collector).
View case study →
ASELSAN Gölbaşı
Aerospace & defence
Solar air preheating feasibility and system integration concept for the REHİS facility.
Explore industrial applications ↗Engineering first.
Savings by design.
Every industrial site is different. SolarWall solutions begin with the right thermal demand, placement and integration strategy.
Our project approach ↗Understand your heat demand
Baseline fuel consumption, airflow, operating hours and supply-air requirements.
Assess site feasibility
Evaluate collector area, orientation, shading, structure and mechanical connections.
Engineer the integration
Model performance and design the solar air path, controls and HVAC connections.
Implement and measure
Commission the system and monitor results where included in the project scope.
Performance is best
understood on site.
Published customer references and case-study documentation connect technical capability to practical heating applications.

Toyota Motor Manufacturing France
A solar air heating façade integrated with ventilation at Toyota’s French manufacturing plant.
400 m² · SolarWall collector
View case study ↗
Türk Tuborg Malt Facility
High-volume renewable air preheating integrated with industrial malt drying.
315 m² · Collector area
View case study ↗
Eczacıbaşı VitrA Karo
Thermal energy preheating for ceramic spray-drying operations.
1,450 m² · Collector area
View case study ↗Technology with a global track record. Local questions, local engineering.
Selected industrial references and project locations shown for context. Global installations do not imply delivery by SolarWall Europe.

Perforation is a brand illustration. Yellow tones indicate latitude bands, not PVGIS solar irradiation data.
Built for a wide range of industrial conditions.
From automotive and aviation facilities to industrial manufacturing, applications vary with ventilation loads, heating demand and building orientation.
- Toyota | Valenciennes, France
- Türk Tuborg | İzmir, Türkiye
- VitrA | Bozüyük, Türkiye
- Philip Morris | İzmir, Türkiye
- TUSAŞ | Ankara, Türkiye
Project status and supporting evidence vary. See the individual project documentation before interpreting these as commissioned European projects.
Review project referencesHow much solar heat could your facility generate?
Explore an illustrative annual thermal output based on location and collector area. This is not a project-specific performance forecast.
Estimated annual collector heat potential (MWh/year)
- Potential per m² of collector
- —
- Calculation status
- Illustrative assumptions
Preliminary illustration only. The solar irradiation inputs and performance factors have not been independently validated for this website. This is not a prediction of heat available to your processes, a performance guarantee or an engineering quotation.
Methodology and assumptions
Illustrative model: annual collector heat potential (MWh) = collector area (m²) × provisional annual irradiation (kWh/m²) × 0.80 assumed orientation adjustment × 0.40 assumed collection factor ÷ 1,000. These two factors are placeholders, not measured SolarWall system performance. The irradiation input is not established as a vertical-façade, orientation-specific PVGIS series.
Provisional location inputs (kWh/m²/year): Barcelona 1,650; Madrid 1,800; London 1,000; Berlin 1,150; Paris 1,200; Rome 1,600; Istanbul 1,400. Results do not account for shading, system type, hourly weather, collector airflow, operating times, building load, or usable delivered heat. Before a project estimate, use orientation-specific PVGIS irradiation data and manufacturer-validated performance modelling.
What could solar heat do for your facility?
Share a few details about your operations. We'll help determine whether SolarWall deserves a closer technical assessment.
Request a feasibility assessment ↗